IntegrX-HPX™ Sanitary Rupture Disc

Features

  • Versitle installation options, including between industry standard ferrules, NovAseptic® Connectors and others
  • Each disc is manufactured and tested to optimize service life and performance*
  • Crevice free design per ASME BPE-2019 Appendix M Spray Device Coverage Test
  • Cleanability test performed on inlet side of 100% of rupture discs using Dye Penetrant per ASME BPVC Section V to ensure crevice free design
  • CIP and SIP cleanable to ASME BPE requirements
  • Ideal for liquid or gas/vapor applications**


* The ASME BPE Standard provides requirements applicable to the design of equipment used in the biotech, pharmaceutical and personal care industries, including aspects related to sterility and cleanability, materials of construction, dimensions and tolerances, surface finish, material joining and seals. It applies to components in contact with the product, raw materials or intermediates. Systems that are a critical part of the manufacturing process, such as water for injection (WFI), clean steam, filtration and intermediate storage may also abide by this standard.

** To optimize service life and rupture disc performance, Continental Disc Corporation manufactures and tests each IntegrX-HPX rupture disc order for compressible or incompressible relief conditions as required by your application. IntegrX-HPX rupture discs manufactured and tested only for compressible (gas/vapor) relief conditions may not function properly in an incompressible (liquid) application Please state in your specifications and orders if a scenario exists for relief of incompressible media or if relief conditions exist only for compressible media.

Technical Data

  • Sizes: 1” (25mm) to 4” (100mm)
  • Rupture Disc Materials: 316 Stainless Steel, Alloy C276, Alloy C22
  • Ferrules Material: 316/316L Stainless Steel as standard
  • Burst Pressure Range: 15 psig to 500 psig (1.03 barg to 34.5 barg)
  • Temperature Range: -320°F to 500°F (-196°C to 260° C)
  • Manufacturing Range: Zero
  • Burst Tolerance:
    • +/- 5% over for marked burst pressure 40 psig (2.76 barg) and
    • +/- 2 psig (0.138 barg) @ 40 psig (2.76 barg) and under
  • Burst to Operating Ratio:
    • 95% of the burst pressure for settings with 40 psig (2.76 barg)
    • For burst pressures below 40 psig, 95% of the burst pressure setting minus the burst tolerance
  • Sanitary Ferrule Connections: ASME BPE, ISO 2852, DIN 32676
  • Global certifications and approvals including ASME (UD), PED (CE),UKCA, CRN

Sustainability

By implementing INTEGRX-HPX™ rupture discs, your process can:

  • Lower environmental impact – Read blog for full details
  • Reduce energy consumption
  • Minimize waste generation
  • Enhance process efficiency
  • Comply with industry standards
  • Continental Disc maintains a system for tracing products back to Conflict Free Smelters and documents that
    all purchased materials are from non-conflict sources. Click here for more information

Overall, the INTEGRX-HPX™ rupture disc is a sustainable and reliable solution for various industrial applications.

Make An Enquiry

    Information provided on this form will be used for sales follow up and for marketing purposes. You can opt out at any time. Click here to read our privacy policy for full details.
  • This field is for validation purposes and should be left unchanged.

Let's Connect!

Get in touch with our dedicated team. We are here to help!